Imrt interplay effect
Witryna2 gru 2016 · The purpose of this study was to evaluate the impact of the motion interplay effect in early-stage left-sided breast cancer intensity-modulated radiation … Witryna4 lut 2024 · In IMRT, the interplay effect leads to hot and cold spots within the treatment volume, and dose variation up to 18% in a single fraction has been observed [ 5 ]. The interplay effect is widely studied for lung tumors but much less literature is …
Imrt interplay effect
Did you know?
WitrynaReceived 12 December 2005; accepted 19 July 2006 Intrafraction organ motion during the dynamic delivery of intensity-modulated radiation therapy (IMRT) treatment of lung … WitrynaThe authors present a segment-based convolution method to account for the interplay effect between intrafraction organ motion and the multileaf collimator position …
Witryna•The combination of dose blurring and interplay effects resulted in reductions in the mean dose (compared to static delivery, with deep breath motion) ranging from: •2.6 to 7.4% for enhanced dynamic wedge •1.2 to 2.5% for field-in-field •0.9 to 4.0% for IMRT •Analysis of interplay patterns suggested effects started to wash Witryna28 lis 2006 · Intra-fraction organ motion during the dynamic delivery of IMRT treatment of lung tumors may cause unexpected hot/cold spots even within the target volume, due …
Witryna28 lut 2014 · interplay effect in the dynamic IMRT delive ry. Thi s model can be clini c ally used to quantify the dosimetric uncertai nty due to the inte rplay effect prior to the treatme nt delivery. 1. WitrynaPurpose: The effects of respiratory motion on the tumor dose can be divided into the gradient and interplay effects. While the interplay effect is likely to average out over …
Witryna15 maj 2008 · @article{osti_21120678, title = {Quantifying the interplay effect in prostate IMRT delivery using a convolution-based method}, author = {Li, Haisen S and Chetty, Indrin J and Solberg, Timothy D}, abstractNote = {The authors present a segment-based convolution method to account for the interplay effect between …
Witryna26 paź 2024 · One study found significant changes in target coverage for highly modulated fields and large motion amplitude 10 while another reported minimal interplay even as target excursion increased to 2–3 cm. 11 A third study reported that interplay effects would be insignificant with sufficient margin. 12 Another reported negligible … matthews eastmoore sarasotaWitrynaIMRT interplay effect using a 4DCT MC dose calculation N93 (a) (b) (c) (d) Figure 2. End of inhale (EOI) CT scan of 1D motion phantom in axial (a), sagittal (b) and coronal (c) view with contours for the concave target. Photograph of 1D motion phantom (d). of the phantom, we used a prostate plan with a dominant intra-prostatic legion boost), here is the maldivesWitryna1 sie 2024 · In the case where a tumour moving with respiration is treated with a dynamic treatment modality, such as intensity modulated radiation therapy (IMRT) or … here is the little door howellsWitryna26 paź 2024 · Seco et al showed that for a sliding widow and step-and-shoot IMRT, up to an 18% dose variation was observed for a single fraction, under similar measurement … here is the list or here are the listWitryna1 sty 2011 · The interplay effect does not result in unexpected dose variation, and the dose gradient at the edge of the PTV, obtained from dynamic measurement, agreed within 1 mm compared with static-convolved measurement. ... An experimental investigation on intra-fractional organ motion effects in lung IMRT treatments. Phys … matthews edge aggregatesWitryna23 lis 2024 · Kardar L et al. 2014 Evaluation and mitigation of the interplay effects of intensity modulated proton therapy for lung cancer in a clinical setting Pract. Radiat. Oncol. 4 e259–68. Crossref Google Scholar. Li Y et al. 2014 On the interplay effects with proton scanning beams in stage III lung cancer Med. Phys. 41 021721. Crossref … matthews eastmoore attorneysWitryna7 kwi 2024 · The internal target volume (ITV)-based IMRT method can be used to reduce the effect of respiratory tumor motion. In this study, the effect of tumor motion on the dosimetric accuracy during ITV-based IMRT was investigated. ITV-based IMRT plans for a total of ten cases of liver cancer were prepared in TomoTherapy (Tomo) and … matthews edwards